iDP-460 User’s Manual
20 CITIZEN
7. SERIAL INTERFACE
7.1 Specifications
(1) Synchronous system: Asynchronous
(2) Baud rate: 150, 300, 600, 1,200, 2,400, 4,800, 9,600, or 19,200 bps (User selectable)
(3) Configuration of one word
• Start bit : 1 bit
• Data bits : 7 or 8 bits (User selectable)
• Parity bit : Odd, even, or none (User selectable)
• Stop bit : 1 bit or more
(4) Signal polarity
RS-232C
• Mark = Logic "1" (-3 V to -12 V)
• Space = Logic"0"(+3Vto+12V)
(5) Received data (RD signal)
RS-232C
• Mark = 1
• Space = 0
(6) Reception control (DTR signal)
RS-232C
• Mark : Data transfer disabled
• Space : Data transfer enabled
(7) Transmission control (TD signal)
• Status transmission
P-250 = Transmits "A"(41h)
P-900R = Transmits "H"(48h)
• Printer state transmission
Transmits the data indicating the 1-byte state. (See 10. PRINT CONTROL FUNCTIONS)