Chapter 4 Printer Adjustment
48
4 Adjustable Sensor
(For CLP-7001/7401)
The adjustable sensor is the optional for CLP-7002.
Operating procedure:
1. Move the adjustable sensor to your required detection position by tuning the adjustable
knob. Measure your detection position beforehand. To set the detection position, align
the scale marking on top of the upper guide rail with the sensor position mark (yellow)
on the upper of the sensor. The movable range of the adjustable sensor is shown
below.
2. Set the liner and close the upper guide rail and set voltage to 3V.
For voltage setting, see Section 5: System Maintenance Mode, Chapter 2.
A
d
j
ustable knob
Mark
(y
ellow
)
Upper guide rail
Left edge of paper
0 mm
118 mm (max. paper width)
59 mm (sensor usable range)
Adjustable sensor
movable range