2.2.8 Panel Switch Commands
ESC c 5 n
[Function] Enabling/disabling the panel switches
[Code] <1B>H<63>H<35>H<n>
[Range] 0 255
[Outline] Enabling/disabling the FEED switch.
• “n” is valid only for the lowest bit (n0).
• Control by the lowest bit (n0) is shown as follows:
n0 Condition
0 FEED switch valid
1 FEED switch invalid
[Caution] • When the FEED switch is disabled with this command, the paper cannot be fed by
operating the FEED switch.
• While switch operation is waited at the execution of macro, the FEED switch is always
enabled regardless of the setting of this command but no paper feed operation is
carried out.
[Default] n=0
[Sample Program]
LPRINT CHR$(&H1B);"c5";CHR$(0); ・・・・・ When enabling the FEED switch
LPRINT CHR$(&H1B);"c5";CHR$(1); ・・・・・ When disabling the FEED switch