GS l n1L n1H n2L n2H
[Function] Setting the Black mark length
[Code] <1D>H<6C>H<n1L><n1H><n2L><n2H>
[Range] 0n1L255 (24 n1L + n1H x256 360)
0n1H1
8n2L30
n2H = 0
[Outline] Define the specifications (length) of the Black mark used.
n1: Sets the Black mark length
n2: Sets the Black mark gap length
n1 and n2 are specified units of millimeters.
Divide the maximum Black mark length by 256 with the quotient designated as n1L
and the remainder as n2H. Accordingly, the Black mark length available for setting will
be n1L + n2H x256.
[Caution] • If the specified length is outside of Black mark specifications, the default length is
set.
• 360 mm is the maximum Black mark length allowed to define and 24 mm is the
minimum.
• 30 mm is the maximum allowable Black mark gap length to define and 8 mm is the
minimum.
[Default] The following default values are set when memory switch SW4-1 is set to ON.
n1L = 25
n1H = 0
n2L = 8
n2H = 0
n1
n2
Page view 109