Citizen CT-S2000 Specifications Page 140

  • Download
  • Add to my manuals
  • Print
  • Page
    / 191
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 139
- 138 -
DLE DC4 fn m t (Specification of fn = 1)
[Function] Outputting specified pulse in real-time
[Code] <10>H<14>H<fn><m><t>
[Range] fn = 1, 0m8, 1t8
[Outline] • A signal specified with “t” is output to the connector pin specified with “m”.
m Connector Pin
0 Pin No. 2 of drawer kick-out connector
1 Pin No. 5 of drawer kick-out connector
• Set the ON time/OFF time to t x100 ms, respectively.
[Caution] • When receiving a code row coinciding with the code configuring this command, the
same operation as this command takes place and attention by the user is required.
Example: When corresponding code row is present in bit image data.
• This command must not be used between other command code rows.
Example: This command is used in the bit image data.
• This command is ignored under the following conditions.
• During sending block data
• During output of signal to drawer kick connector
• During occurrence of error
[See Also] ESC p