- 49 -
ESC 3 n
[Function] Setting line feed rate of minimum pitch
[Code] <1B>H<33>H<n>
[Range] 0 255
[Outline] Sets the line feed width per line to [n basic calculation pitch] inches.
[Caution] • The line feed width can be set separately for the STANDARD and PAGE MODES.
• The basic calculation pitch is set by GS P. Once defined, the line feed width is not
changed if the basic calculation pitch is changed by GS P.
• Fractions resulting from calculation are corrected with the minimum pitch of the
mechanism, and the remainder is omitted.
• In STANDARD MODE, this command uses the vertical (paper feed direction) basic
calculation pitch (y).
• In PAGE MODE, this command acts differently depending on the start point:
(1) If the start point specified by ESC T is top left or bottom right, the command
uses the vertical (paper feed direction) basic calculation pitch (y).
(2) If the start point specified by ESC T is top right or bottom left, the command
uses the horizontal (perpendicular to the paper feed direction) basic calculation
pitch (x).
• The maximum settable line feed width is 1016 mm (40 inches). A setting greater than
this maximum is trimmed to the maximum.
[Default] When memory switch 3-7 is OFF: Line feed is approx. 4.23 mm.
When memory switch 3-7 is ON: Line feed is approx. 3.75 mm.
[See Also] ESC 2