fn=69: Function 69 Setting error correction level of PDF417
GS ( k pL pH cn fn m n PPU-700II only
[Code] <1D>H<28>H<6B>H<pL><pH><cn><fn><m><n>
[Range] (pL+pH×256)=4 (pL=4, pH=0)
cn=48
fn=69
m=48, 49
48 n 56≦≦ (when m=48 is specified)
1n40≦≦ (when m=49 is specified)
[Outline] [The specification which is common to the model]
Sets error correction level of PDF417
When m=48, set by the level of n.
n Fnction Error Correction Code Words
48 Selects error correction level 0. 2
49 Selects error correction level 1. 4
50 Selects error correction level 2. 8
51 Selects error correction level 3. 16
52 Selects error correction level 4. 32
53 Selects error correction level 5. 64
54 Selects error correction level 6. 128
55 Selects error correction level 7. 256
56 Selects error correction level 8. 512
When m=49, [set by the ratio (nx10%)] to the number of data code words.
Calculation result (A) = Value of (number of data code words xnx0.1) rounded to the
nearest one.
Result
(A)
Fnction Error Correction Code Words
0 to 3 Selects error correction level
1.
4
4 to 10 Selects error correction level
2.
8
11 to 20 Selects error correction level
3.
16
21 to 45 Selects error correction level
4.
32
46 to 100 Selects error correction level
5.
64
101 to 200 Selects error correction level
6.
128
201 to 400 Selects error correction level
7.
256
401 to Selects error correction level
8.
512
[Default] m=49, n=1