Citizen PPU-700II Specifications Page 88

  • Download
  • Add to my manuals
  • Print
  • Page
    / 200
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 87
- 86 -
fn = 5, 53: Function 5 Sending Key Code List of Stored Record
GS ( C pL pH m fn b
[Code] <1D>H<28>H<43>H<pL><pH><m><fn><b>
[Range] pLpH×256)=3pL3, pH0
m0
fn=5, 53
b0
[Outline] Sends key code list of record existing in user NV memory.
Hex. Decimal Data size
Header 37H 55 1 byte
Identifier 71H 113 1 byte
Status 40H or 41H 64 or 65 1 byte
Data
20HFEH 32254 280 bytes
NUL 00H 0 1 byte
• Data is a data group with a list of key codes.
Transmission data group when record is not detected is as shown below.
Hex. Decimal Data Size
Header 37H 55 1 byte
Idenifier 71H 113 1 byte
Status 40H 64 1 byte
NUL 00H 0 1 byte
After sending [Header - NUL], receives a response from the host and executes the next
processing corresponding to the response.
• In case of “Status (with continuous block): hexadecimal number = 41H / decimal
number = 65”
Response
ASCII Decimal
Content of Processing
ACK 6 Sends next data group.
NAK 21 Resends previous data group.
CAN 24 Cancels processing.
• In case of “Status (last block): hexadecimal number = 40H / decimal number = 64”
Response
ASCII I Decimal
Content of Processing
ACK 6 Terminates processing.
NAK 21 Resends previous data group.
CAN 24 Cancels processing.
Page view 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 199 200

Comments to this Manuals

No comments